GPR010-12V
High Voltage DC contactor 10Amps@450VDC (DC relay). The relay is perfect for pre-charge applications in automotive, solar, ups and Energy Storage Systems. The magnets take care for the arc blowout. Coil voltage 12VDC.
Share:
Downloads
To get a more deep overview of the total GPR product line, please download one of the pdf’s below:
Download Extended Catalog GPR-Series
| Number of poles | 1 pole |
| Operating Voltage | up to 450VDC |
| Coil voltage | 12VDC |
| Rated impulse withstand voltage, U imp | 4kV |
| Conventional thermal Current, Ith | 10 Amps |
| Shorttime withstand current | 2 min: 15 Amps |
| Unnamed variable | 15 min: N.A. |
| Mechanical durability | > 200.000 cycles |
| Electrical durability | 10A, 450VDC, 150.000cycles (at 360 cycles/Hr) |
| Voltage drop | 0.5V@10Amps |
| Operating time | Max. 50ms |
| Release time | Max. 30ms |
| Insulation strength (initial) | Min. 100MΩ (@500VDC) |
| Size, W × H × D( mm ) | 56x28x45 |
| Temperature range | -40 – 85C |
| Humidity | 5-95% R.H. |
| Weight | 85 gr |
| Certification | CE, CCC |