GPR-M250-24V
High Voltage DC contactor 250Amps, 1000VDC (DC relay). The relay is perfect for applications in automotive, solar, UPS and (Battery) Energy Storage Systems. The gas in the ceramic chamber and the magnets take care for the arc blowout. Coil voltage is 24VDC, economiser is integrated.
Share:
| Number of poles | 1 pole |
| Operating Voltage | up to 1000VDC |
| Coil voltage | 24VDC |
| Rated impulse withstand voltage, U imp | 6kV |
| Conventional thermal Current, Ith | 250 Amps |
| Shorttime withstand current | 2 min: 500 Amps |
| 15 min: 350 Amps | |
| Mechanical durability | > 200.000 cycles |
| Electrical durability | 125A, 1000VDC, 1.000cycles (at 360 cycles/Hr) |
| Voltage drop | 0.02V@20Amps |
| Operating time | Max. 30ms |
| Release time | Max. 10ms |
| Insulation strength (initial) | Min. 100MΩ (@500VDC) |
| Size, W × H × D( mm ) | 92 x 45 x 87 |
| Temperature range | -40 – 85C |
| Humidity | 5-95% R.H. |
| Weight | 500 gr |
| Certification | CE, UL, CCC |